Power Requirement
20 to 50 Vdc (two wire)
-
Output
4-20 mAdc
-
Measurement Range
0-1% water, 0-5% water, 0-10% water,
0-30% water, 0-50% water
-
Ambient Temperature
-30° to +140° F
-
Housing Seal Rating
Nema 4X
-
Accuracy
± 0.1% water for 1% and 5% ranges.
± 5% of span for 10, 30, and 50% ranges
(at standard conditions)
-
Digital Indicator (Remote electronics only)
3+ digit liquid crystal display; 1/2" height (factory calibrated for %water.)
-
Step Response
Less than 4 sec. to 90% of final output
-
Repeatability
± 0.5% span
-
Resolution
0.2% span
-
Hazard Classification
Sensing element: Intrinsically safe for all hazards.
-
Electronics: Intrinsically safe for Groups C & D (Div. 1 & 2) when supplied from an intrinsically safe power source, and explosion proof housing for Groups C & D (Div. 1&2) (Approvals worldwide)