IntelliPoint RF

Overview

Simply install the IntelliPoint RF Series into the tank and apply power …that's it! 
Unlike other RF or capacitance systems that require calibration via setpoint potentiometers, jumpers, magnets, or pushbuttons. The IntelliPoint RF Series reliably detects the absence or presence of material without any adjustments.

The IntelliPoint RF Series software continuously monitors the application for changes in composition, dielectric or conductivity, and maintains a repeatable trip point on the probe. Other RF and capacitance systems require calibration adjustments when the process material is changed. 

Since the IntelliPoint RF Series recognizes changes in material,it is ideal for non-dedicated tanks that are used for a wide variety of products.

Diverse Applications

  • Line Powered
  • Two-Wire
  • SIL Conforming
  • Sanitary
  • Manual Set-point

Intelligent Electronics

  • No calibration or setpoint adjustments
  • Ignores changes in dielectric or conductivity
  • Automatically recognizes and ignores coatings to prevent false alarms
  • Continuous self-test monitors circuits and sensing elements for faults
  • Universal power supply automatically detects input power source

Dual Compartment Housing

  • Power Supply is isolated from intrinsically-safe sensing element and circuit board

Remote or Integral Electronics

  • Unlike many technologies, electronics can be remote mounted to a convenient or safe location

Specifications for Two Wire (RNT Series) IntelliPoint

Technology:
RF Admittance

Calibration:
None

Output:
Relay or Current

Modes Of Operation:
High and Low Level

Repeatability:
2 mm (0.08 inch)conductive liquids

Response Time:
less than one second.

Ambient Electronic Temperature:
-30 to 70 °C (-28 to 158 °F)KEMA.
-40 to 70 °C (-40 to 158 °F)FM /CSA

Storage Temperature:
-40 to 85 °C (-40 to 185 °F)

Self Check:
AutoVerify automatically and continuously checks electronics and sensing element for faults.
Manual Certify checks that the AutoVerify circuits are functioning.

Time Delay:
0-60 seconds,forward or reverse-acting

Supply Voltage:
13-30VDC

Power Consumption:
2 watts maximum

Output:
8 mA -Alarm
16 mA -Normal
22 mA -Fault

or

8 mA -Normal
16 mA -Alarm
5 mA -Fault

Housing:
Dual Compartment,Powder-Coated aluminum with two cable entries

Cable Entry:
M20 x 1.5 CENELEC
3⁄4-inch NPT FM/CSA

Ingress Protection:
IP66 NEMA 4X

 
Download



IntelliPointRF
 
 
Access Guide Access Guide Access Guide Access Guide Access Guide Access Guide Access Guide Access Guide Access Guide Access Guide Access Guide Access Guide Access Guide Access Guide