The new DR7000 has State-of-the-Art components and more advanced design solutions. The DR7000 is able to operate over a larger bandwidth: This ensures sharper resolution and higher accuracy. The higher signal dynamics of the DR7000 allow the accurate detection of even the smallest level changes.
-
Easy Navigation Display
Choice of different Touch Screens: (tank illustration, bargraph, signal and reflectivity screen)
-
2-Wire
Class I Div1, Zone 0 Installation
-
Process Seal Ensures Vessel Integrity
-
Antenna Types and Materials for all Applications
Vessel Obstructions Ignored
Agitators and other objects such as struts, inlets, ladders, have less effect on signal reduction.
The 26GHz FMCW signal is easier to evaluate and the results are more accurate and repeatable.
Agitated Surface
State-of-the-Art signal processing and a 2MHz bandwidth allow the DR7000 to determine the true level in the tank despite agitated surfaces.
Makes Level Gauging Easier than Ever
Wizard Works Wonders
Setting up a 2-wire level gauge couldn’t be easier:
Simply fit the gauge to the tank, wire it up and switch it on:
-
Step 1 – The DR7000 tests itself to make sure its electronics are working perfectly.
-
Step 2 – The DR7000's Wizard walks you through a simple series of questions to define your tank and the product you want to measure.
-
Step 3 – That’s all you need. Your DR7000 is already measuring.
Interactive Help
Not certain what to do? You don’t need a handbook. Simply wait 10 seconds, the help screen will appear and tell you what to do.
Specifications
Input
Function K-band 26 GHz FMCW radar
Parameter Level, distance, volume and reflectivity
Min. Tank Height 0.5 m / 1.5 ft
Max. Range 40 m / 131 ft
Dead Zone Antenna length + 0.1 m antenna length + 4”
Output Signal
Output signal 4 - 20 mA HART® or 3.8 - 20.5 mA acc. to NAMUR NE 43
Accuracy 0.05% (rel. 20 mA; 20°C / 68°F)
Resolution ±2 µA
Temperature Drift Typically 50 ppm/K
Error Signal High: 22 mA; Low: 3.6 mA acc. to NAMUR NE 43
Max. Load 350 ohm
Measuring Accuracy - Reference conditions acc. to IEC770
Temperature +20°C ±5°C / +68°F ±9°F
Pressure 1013 mbar abs. ±20 mbar 14.69 psig ±0.29 psig
Relative Humidity 60% ±15%
Resolution 1 mm / 0.04 “
Accuracy ±3 mm / ±0.12”
Beam Angle: DN 40 / ANSI 1 1/2” 20°
DN 50 / ANSI 2” 15°
DN 80 / ANSI 3” 10°
Application Conditions
Ambient Temp. -40…+80°C / -40…+175°F; EEx i: -40…+60°C / -40…+140°F
Storage Temp. -40…+85°C / -40…+185°F
Flange Temp. -40…+150°C / -40…+300°F (Ex: refer to relevant device spec.)
Shock Resistance 100°C/min
Process Conditions
Operating Pressure 1…40 bar / -14.5…580 psig; subject to process connection and temp.
Dielectric Constant 1.5
Vibration Resistance IEC 68-2-6 and prEN 50178
(10...57Hz: 0.075 mm / 57...150 Hz: 1 g)
Protection Category IP 66/67 equiv. to NEMA 6-6X
Mechanical Data
Housing Aluminium
Wetted Parts Stainless steel (1.4404 / 316L);
Hastelloy C-22 (2.4602)
Process Fitting Stainless steel (1.4404 / 316L);
Hastelloy C-22 (2.4602)
Gaskets Viton (-40…+150°C / -40…+300°F); Kalrez 6375 (-20…+150°C / -5 …+300°F)
Process Connection
Thread G 1 1/2; NPT 1 1/2
Flange DN 40…DN 150 (PN 40 / PN 16); 1 1/2”…8” (150 lb / 300 lb); 10 K (40…100A)
Electrical Connection - 2-Wire Power Supply
Terminals Output 1 Non-Ex/ EEx i 24 V DC (14 … 30 V DC)
EEx d 24 V DC (20 … 36 V DC)
Cable Entry Terminals M20x1.5; 1/2 NPT; G 1/2
0.5…1.5 mm²
|