The new DR7100 with its more advanced design solutions has higher signal dynamics. Sharper Pulses measure thinner interfaces. The superior Time Base Stability allows better reproductibility, which translates to better reliability.
-
Easy Navigation & Viewing
Choice of different Touch Screens: (tank illustration, bargraph, oscilliscope...)
-
2-Wire
Class I Div1, Zone 0 Installation
-
Special Process Separator for Extreme Conditions
-
Probe Types and Materials for all Applications
Most Stable Measurement
Despite disturbances such as strongly agitated surfaces, foam and coating of the probe or fine dust in the tank, DR7100 will continue to measure where competitors’ devices fail.
Measures any Product ...
Most 2-wire TDR devices measure down to a dielectric of 1.5. As a result, many organic compounds are not measured properly. DR7100 measures down to 1.4 (and even 1.1 using superior tank-bottom following mode).
... in any Application
5 different probes means there’s not an application that we can’t handle.
Makes Level Gauging Easier than Ever
Wizard Works Wonders
Setting up a 2-wire level gauge couldn’t be easier:
Simply fit the gauge to the tank, wire it up and switch it on:
-
Step 1 – The DR7100 tests itself to make sure its electronics are working perfectly.
-
Step 2 – The DR7100s Wizard walks you through a simple series of questions to define your tank and the product you want to measure.
-
Step 3 – That’s all you need. Your DR7100 is already measuring.
Interactive Help
Not certain what to do? You don’t need a handbook. Simply wait 10 seconds, the help screen will appear and tell you what to do.
Input
Function Time Domain Reflectometry (TDR)
Parameter Level, distance, volume and / or interface
Max. measuring range Double rod 8mm / 0.3” 4m / 13ft
Single rod 8mm / 0.3” 4m / 13ft
Coaxial 22mm / 0.9” 6m / 20ft
Double cable 4mm / 0.15” 35m / 115ft
Single cable 4mm / 0.15” 35m / 115ft
Single cable 8mm / 0.3” 35m / 115ft
Output Signal
Output signal 1 4 - 20mA HART® or 3.8 - 20.5 mA acc. to NAMUR NE 43
Output signal 2 4 - 20mA or 3.8 - 20.5 mA (Optional) acc. to NAMUR NE 43
Accuracy 0.05% (rel. 20 mA; 20°C / 68°F)
Resolution ±2 µA
Temperature Drift Typically 50 ppm/K
Error Signal High: 22 mA; Low: 3.6 mA acc. to NAMUR NE 43
Max. Load 350 ohm
Measuring Accuracy - Reference conditions acc. to IEC770
Temperature +20°C ±5°C / +68°F ±9°F
Pressure 1013 mbar abs. ±20 mbar 14.69 psig ±0.29 psig
Relative Humidity 60% ±15%
Resolution 1 mm / 0.04 “
Accuracy In Direct Mode
Liquids ±3 mm / ±0.12”
when L < 10 m / 33 ft; ±0.03% of measured distance, when L > 10 m / 33 ft
Powders ±20 mm / ±0.8”
Interface ±10 mm (r Constant)
Application Conditions
Ambient Temp. -40…+80°C / -40…+175°F; EEx i: -40…+60°C / -40…+140°F
Storage Temp. -40…+85°C / -40…+185°F
Flange Temp. -40…+150°C / -40…+300°F (Ex: refer to relevant device spec.)
Shock Resistance 100°C/min
Process Conditions
Operating Pressure 1…40 bar / -14.5…580 psig; subject to process connection and temp.
Dielectric Constant >_ 1.4 Coaxial Probes >_ 1.6 For single and Twin Probes
Vibration Resistance IEC 68-2-6 and prEN 50178
(10...57Hz: 0.075 mm / 57...150 Hz: 1 g)
Protection Category IP 66/67 equiv. to NEMA 6-6X
Mechanical Data
Housing Aluminium
Wetted Parts
Rod Stainless steel (1.4404 / 316L);
Hastelloy C-22 (2.4602)
Coaxial Stainless steel (1.4404 / 316L);
Hastelloy C-22 (2.4602)
Cable (4mm /0.15") Stainless steel (1.4401 / 316);
Hastelloy C-22 (2.4602)
Process Fitting Stainless steel (1.4404 / 316L);
Hastelloy C-22 (2.4602)
Gaskets Viton (-40…+150°C / -40…+300°F); Kalrez 6375 (-20…+150°C / -5 …+300°F)
Process Connection
Thread G 3/4"...1 1/2"; NPT 3/4"...1 1/2"
Flange DN 25…DN 150 (PN 40 / PN 16); 1”…8” (150 lb / 300 lb); 10 K (40…100A)
Electrical Connection - 2-Wire Power Supply
Terminals Output 1 Non-Ex/ EEx i 24 VDC (14 … 30 VDC)
EEx d 24 V DC (20 … 36 VDC)
Terminals Output 2 Non-Ex/ EEx i / EEx d 24 VDC (10 … 30 VDC)
Cable Entry Terminals M20x1.5; 1/2 NPT; G 1/2"
0.5…1.5 mm²
|